1U data centre access switch with 48 x 1G/10G SFP+ ports, 8 x 40G/100G QSFP28 ports and 2.56 Tbps switching capacity. The chassis is equipped with two RG-PA550I-F power modules and four fan modules. Transceivers are needed for every port.
The RG-S6250-48XS8CQ is a 1U data centre access switch with 48 x 1G/10G SFP+ ports and 8 x 40G/100G QSFP28 ports. Switching capacity is 2.56 Tbps.
Ruijie position it as a 10GE data centre access switch. It lists M-LAG, VSU and de-stacking for higher availability, and PFC and ECN support for a lossless RDMA network. Data centre features include VXLAN routing and bridging and EVPN VXLAN.
All service ports are SFP+ or QSFP28 cages, so there is no copper service port. The chassis has two power module slots and four fan module slots, with 1+1 power redundancy and fan redundancy, and maximum power consumption of 300 W. It sits with our other data networking and network switches.
| Dimensions (W x D x H) | 442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.) |
| Rack height | 1 RU |
| Unit weight | 5.6 kg (12.35 lbs, empty chassis); 8.2 kg (18.08 lbs, a chassis installed with two power modules and four fan modules) |
| Switching capacity | 2.56 Tbps |
| Packet forwarding rate | 1920 Mpps |
| Service port | 48 x 1G/10G SFP+ ports; 8 x 40G/100G QSFP28 ports |
| Management port | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| USB port | 1 x USB 2.0 port (Type A connector) |
| Module slot | 2 x power module slots; 4 x fan module slots |
| Power consumption | Maximum power consumption: 300 W; Typical power consumption: 165 W; Static power consumption: 98 W |
| Power input | RG-PA550I-F (AC input): Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 7.2 A to 3.5 A (100 V AC to 240 V AC); Power port type: C14; RG-PA550I-F (HVDC input): Rated input voltage: 240 V DC; Maximum input voltage: 180 V DC to 310 V DC; Rated current: 3.6 A; Power port type: C14; RG-PHD550I-F (AC input): Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 10 A; Power port type: C14; RG-PHD550I-F (HVDC input): Rated input voltage: 336 V DC; Maximum input voltage: 160 V DC to 400 V DC; Rated input current: 10 A; Power port type: C14; RG-PD800I-F (DC input): Rated input voltage: –48 V DC; Maximum input voltage: –36 V DC to –72 V DC; Rated input current: 23 A; Power port: three-pin power port |
| Temperature | Operating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
| Humidity | Operating humidity: 10% RH to 90% RH (non-condensing); Storage humidity: 5% RH to 95% RH (non-condensing) |
| Altitude | Operating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.) |
| Cooling | Air cooling, front-to-rear airflow (port-side intake) |
| Layer 2 protocols | IEEE802.3ae (10GBase), IEEE802.3ak, IEEE802.3an, IEEE802.3x, IEEE802.3ad (static link aggregation, LACP, M-LAG), IEEE802.1p, IEEE802.1Q; IEEE802.1D (STP), STP root guard, and BPDU guard; IEEE802.1w(RSTP), IEEE802.1s(MSTP); IGMP Snooping v1/v2, MLD Snooping, Jumbo Frame(9Kbytes); IEEE 802.1ad (QinQ and selective QinQ), GVRP, Three modes (access, trunk, and hybrid), LLDP, static MAC address, MAC address filtering, MAC address quantity limit |
| Layer 3 protocols (IPv4) | Static routing, BGP4, OSPFv2, IS-IS, RIPv1, RIPv2, MBGP, LPM routing, policy-based routing (PBR), route-policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP, and Any-RP, BFD for BGP/IS-IS/OSPF/static routing, manual tunnel, GRE tunnel |
| Basic IPv6 protocols | Neighbor discovery, ICMPv6, path MTU discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, IS-ISv6, ACLv6, IPv6 TCP/UDP, SNMPv6, IPv6 Ping/Traceroute, IPv6 RADIUS, IPv6 Telnet/SSH, IPv6 FTP/TFTP, NTPv6, IPv6 MIB for SNMP, IPv6 VRRP, IPv6 QoS |
| IPv6 features | Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, IS-ISv6, IPv6 VRRP, MLDv1/v2, PIM-SMv6, manual tunnel, GRE tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel |
| Data center features | VXLAN routing and VXLAN bridging; EVPN VXLAN; VXLAN mapping; IPv4 VXLAN over IPv4; IPv6 VXLAN over IPv4; IPv6 VXLAN over IPv6; IPv6 VXLAN over IPv6; VXLAN over IPv6; M-LAG; OpenFlow 1.3; RDMA, RoCEv2, PFC, and ECN |
| Process | gRPC; sFlow sampling; IPFIX sampling |
| QoS | IEEE 802.1p, ToS, and DSCP priority mapping; ACL traffic classifier, and priority tagging Mark/Remark; Various queue scheduling mechanisms such as SP (PQ), WRR, DRR, SP (PQ)+WRR, and SP (PQ)+DRR; Flexible queue scheduling algorithms based on ports or queues; Congestion avoidance mechanisms such as WRED and tail discarding; Ingress/egress port-based rate limiting and CAR |
| MPLS | MPLS VPN |
| Virtualization | Virtual switching unit (VSU) |
| Buffer management | Buffer usage monitoring and traffic microburst detection |
| High availability | GR for RIP/OSPF/BGP, BFD, DLDP, VRRP, VRRP load balancing/dual-active, BFD for VRRP, REUP, RLDP, 1+1 power redundancy and fan redundancy, and hot swappable line cards and power modules |
| Security features | Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), DDoS/DoS attack defense, ICMP attack defense, unauthorized packet detection, data encryption, source IP spoofing defense, IP scanning attack defense, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL, port-based ACL, or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, Telnet login from specified IP addresses, uRPF, broadcast packet suppression, DHCP snooping, ARP spoofing defense (ARP anti-spoofing), ARP check, and hierarchical user management |
| Management mode | SNMP v1/v2c/v3, Telnet, Console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, NETCONF, Python, fan and power alarm, temperature alarm, and configuration rollback |
| Other protocols | DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP Relay, Proxy ARP, and Syslog |
Every service port is an empty cage, so you need transceivers or DAC cables for each port you use. Ruijie state the chassis is equipped with two RG-PA550I-F power modules and four fan modules. SFP+ ports are listed as 1G/10G and QSFP28 ports as 40G/100G. Tell us your uplink plan and we will check.
We are a supplier, not an installer. We will go through the RG-S6250-48XS8CQ with you before you buy — the transceivers or DAC cables for each port, the speeds you need and the power input for your racks — and depending on your requirements and your area we can recommend a qualified trade installer. We have been operating since 2012 and you can visit our trade counter in Wolverhampton.
48 x 1G/10G SFP+ ports and 8 x 40G/100G QSFP28 ports, plus RJ45 console and MGMT ports and one USB 2.0 port.
Ruijie's page does not list any, so assume every port you use needs a transceiver or DAC cable.
No. Ruijie do not list PoE for this data centre switch.
Two power module slots and four fan module slots, with 1+1 power redundancy and fan redundancy.
Delivery is within 1–3 working days to England, Scotland and Wales. We do not ship to Northern Ireland.
Yes. Our trade counter is at Unit 3, Park View Centre, 243 Dudley Road, Wolverhampton WV2 3JU. Call first so we can confirm the item is there for you.
Questions on specification or compatibility: call 01902 902251, see our FAQ and support pages, or contact us. Trade accounts are available — see trade customers. Browse the full Ruijie Reyee range.
| Product Code | RG-S6250-48XS8CQ |
|---|---|
| Dimensions | 442 mm x 387 mm x 44 mm |
| Manufacturer | Ruijie Reyee |
| Colour | Black |
| Connection Type | Wired |
| Managed | Yes |
We provide tailored support for you and your CCTV system.
Many of our Cameras and Recorders come with a comprehensive 3 year warranty.
We've got a fully functioning show room and IP suite to show you exactly how our CCTV equipment works
As cheap as £10, we will deliver your order 3 to 5 working days!