The Hikvision DS-PM1-O1H-WE is a mains-powered wireless relay module for the AX PRO system — switch a 240 V device on or off from the panel, the app, a schedule, or an alarm event, with no return cable needed.
What it turns a switch into a system
A device that's normally just an on/off switch — a gate motor, an outdoor light, a heater, a ventilation fan — can instead be tied into the AX PRO logic. Trigger it manually from the app, by schedule, by fault condition, or automatically whenever the alarm activates — lighting that comes on the moment an intruder is detected, for instance, without any extra wiring to the panel.
Mains-rated, wall-mount or in-box
Runs directly from 100–240 V AC, so no separate power supply is needed. Small enough to wall-mount or fit inside an 86 mm back box, and switches up to 13 A — enough for a genuine mains load, not just a signalling circuit.
Five scenario types
Configure the relay to fire by alarm, by manual operation, by fault, or on a schedule — one module covers automated lighting, scheduled ventilation and alarm-linked switching without needing separate hardware for each.
Radio built for alarms
Two-way at 868 MHz, AES-128 encryption, free-space range 1.6 km. Three LEDs — register/signal, power, relay status — show its state at a glance.
Specification
- Relay output: 1 × NO/NC, 100–240 V AC, up to 13 A
- Scenarios: by alarm, by operation, by fault, by schedule, by manual
- Power: 100–240 V AC, 50/60 Hz
- Radio: two-way, 868 MHz, AES-128
- Range: 1.6 km free space
- Indicators: register/signal (green/red), power (green), relay status (blue)
- Mounting: wall or inside an 86 mm box
- Operating range: −10°C to +55°C, 10–90% humidity
- Dimensions: 38 × 25 × 18 mm
Worth knowing before you order
This is the mains-voltage version. For a low-voltage DC load — gate strikes, low-voltage lighting, 12/24 V equipment — the DS-PM1-O1L-WE is the correct module instead; wiring a low-voltage device into this one is not appropriate.
Mains wiring should be done by someone competent to do it. This switches genuine mains current.
It needs an AX PRO panel. Part of the AX PRO system only.
Frequently asked questions
What can I switch with it?
Any mains-voltage device up to 13 A — lighting, a fan, a heater, a gate motor's control circuit.
Can it trigger automatically on an alarm?
Yes — one of the five scenario settings is "by alarm", so it can fire the moment the system activates.
Does it need its own power supply?
No — it runs directly from 100–240 V AC mains.
Is this the low-voltage version?
No — for a DC/low-voltage load use the DS-PM1-O1L-WE instead.
Trade prices apply — apply for a trade account or log in. Browse the full AX PRO range or call 01902 902251.