Hikvision DS-K2M061 — secure door control module — relay on the safe side
The DS-K2M061 exists because a lock relay inside an outdoor terminal is only as secure as the terminal's housing. Move the relay indoors and the terminal becomes a reader and keypad only: prise it off and there is nothing to short. Hikvision's DS-KD9633-WBE6 door station, for example, notes that its second lock requires a secure door control unit, and the OSDP-capable terminals such as the DS-K1T673DWX-PROE1 and DS-K1T805MBWX are natural partners. Hikvision publishes this model on its UK site.
What it carries
One lock relay, an exit-button input, a door-contact input, two alarm inputs and one alarm output — the full set of door I/O, relocated to the secure side. An RS-485 port links to the terminal or door station and a Wiegand input is provided.
Power and fitting
12 VDC 0.5 A with a power indicator. Wall mounting at 48 × 115 × 26 mm, small enough for a back box above the door. Rated -40 °C to 70 °C and 0–90% humidity.
DS-K2M061 technical specification
| Doors & readers |
| Lock Control | 1 |
| Exit Button | 1 |
| Door Contact Input | 1 |
| Alarm Input | 2 |
| Alarm Output | 1 |
| Communication |
| RS-485 | 1 |
| Wiegand | 1 |
| General |
| Indicator | 1 for power supply |
| Power Supply | 12 VDC 0.5A |
| Working Temperature | -40 °C to 70 °C |
| Working Humidity | 0% to 90% |
| Installation | Wall Mounting |
| Dimensions | 48 mm × 115 mm × 26 mm (1.9" × 4.5" × 1.0") |
| Model | DS-K2M061 |
What you'll need with it
- A Hikvision terminal or door station with RS-485 that supports a secure door control unit — confirm your model with us
- A 12 VDC 0.5 A supply on the secure side
- The electric lock, exit button and door contact wired to the module instead of the terminal
Frequently asked questions
Why use a DS-K2M061?
Security: the lock relay is on the inside of the door, so damaging or removing the outdoor terminal cannot release the lock.
How does it connect to the terminal?
Over RS-485; a Wiegand input is also provided.
Which devices support it?
Hikvision terminals and door stations that list a secure door control unit — the DS-KD9633-WBE6 requires one for its second lock. Tell us your model and we will confirm.
What are its inputs and outputs?
One lock relay, exit button, door contact, two alarm inputs and one alarm output.
How is it powered?
12 VDC 0.5 A.
Trade pricing
Zenith Security Co is an authorised Hikvision partner supplying genuine UK-specification stock. Prices shown are for trade account holders — contact us for account terms and stock, call 01902 902251, or collect from our Wolverhampton trade counter. Browse all intercoms, the wider access control range, or the full Hikvision range.