In England, private and social landlords must provide a working smoke alarm on every storey used as living accommodation, plus a carbon monoxide alarm in any such room with a fixed combustion appliance (gas cookers excepted). For HMOs, LACORS points to mains-powered, interlinked Grade D alarms, with a Grade A panel in taller shared houses and bedsit blocks of three storeys or more. Ajax lists its FireProtect 2 AC alarms as BS 5839-6 Grade D1, interlinked by radio.
Below, we match them to the Ajax wireless fire alarms we list.
The Smoke and Carbon Monoxide Alarm (England) Regulations 2015, as amended from 1 October 2022, cover private and social landlords. GOV.UK lists the duties:
If a landlord ignores a council remedial notice, GOV.UK puts the fine at up to £5,000 per breach. Unlicensed HMOs are covered too; for licensed HMOs, Schedule 4 of the Housing Act 2004 puts similar duties into the licence, including a declaration on the alarms' condition and position when the council asks. The HMO Management Regulations 2006 (regulation 4) also require the manager to keep fire alarms in good working order.
Yes: both require interlinking; England's regulations do not.
There is no single legal answer: it follows a fire risk assessment. LACORS wrote Housing – Fire Safety (2008, with the Chief Fire Officers Association) as national guidance for councils, fire services and landlords. Its benchmarks for normal-risk property, against Ajax's Residence Line:
| Property type | LACORS benchmark | Ajax Residence Line? |
|---|---|---|
| Single-household let, up to four storeys | Grade D, LD3, interlinked | Yes: AC alarms on a hub |
| Shared house, up to four storeys | Grade D, LD3 plus kitchen, lounge and any risky cellar, interlinked | Yes, with mains models throughout |
| Shared house, five or six storeys | Grade A, LD2 | No: needs a panel system |
| Bedsits with own cooking, one or two storeys | Grade D, LD2 in common areas plus interlinked heat detectors in bedsits; a non-interlinked smoke alarm in each bedsit | Yes, for the Grade D parts |
| Bedsits, three to six storeys | Grade A, LD2 in common areas plus heat detectors in bedsits; a non-interlinked Grade D smoke alarm in each bedsit | Only the bedsit smoke alarms |
| Flat in multiple occupation | Grade D, LD3 plus a kitchen heat detector | Yes |
LD3 covers the escape route only; LD2 adds high-risk rooms such as kitchens and lounges. LACORS predates BS 5839-6:2019, so check with your council's private housing team.
As Designing Buildings summarises BS 5839-6:2019, Grade D1 is mains alarms with a tamper-proof standby battery (D2 has a replaceable one), and F1 runs on tamper-proof batteries alone (F2 on user-replaceable batteries).
FireProtect 2 alarms join an Ajax hub over Jeweller radio:
A qualified electrician still wires each AC alarm to the mains (LACORS notes Grade D alarms can use the lighting circuit), but no interlink cable is needed.
The same hub can also run an Ajax intruder alarm.
Our prices include VAT, delivery is extra, and prices can change:
Worked example: a two-storey single-household let in England. Hub 2 (2G), AC (Heat/Smoke) alarms in the hall and on the landing, and an AC (CO) alarm in the kitchen with the boiler: £418.83 inc VAT, before delivery and the electrician.
The Residence Line suits the Grade D rows of the LACORS table: mains alarms with sealed backup, radio interlink and per-flat silencing. It is not a Grade A system, so bedsit blocks of three storeys or more still need a panel in the common parts; see our wider fire alarm range and ask a fire alarm company. One gap: our only heat-only FireProtect 2 is the SB version, rated F1, so ask us before ordering if your HMO needs a mains kitchen heat alarm. Everything we list from Ajax is on the brand page.
We're a Wolverhampton security equipment supplier, trading since 2012. We don't fit alarms, but we can match Ajax models to your property and recommend a qualified installer depending on the job and area. Call 01902 902251 or contact us online. We ship nationally to England, Scotland and Wales.
Do landlords in England have to interlink smoke alarms?
The England regulations ask for a working alarm on each storey, not interlinking. LACORS benchmarks for HMOs are interlinked, and Scotland and Wales require it.
Can I use battery smoke alarms in an HMO?
Not as the main system: LACORS does not recommend battery-only Grade F systems in HMOs.
Do FireProtect 2 alarms work without a hub?
Yes: each has an 85 dB sounder, and AC models can interlink without a hub through fallback. App alerts and remote tests need a hub.
Do Ajax alarms meet the Welsh rules?
The mains-powered AC models can, interlinked through the hub; the sealed-battery SB models cannot. Check with your council.
How often should HMO alarms be tested?
LACORS suggests testing Grade D alarms monthly with the test button.
Source: Ajax Systems blog; GOV.UK; Housing Act 2004, Schedule 4; HMO Management Regulations 2006; LACORS; Scottish Government; Welsh Government; Designing Buildings; ICO.