The stainless-steel-fronted (/S) 2 MP main unit of Hikvision's KD8 modular door station, (B) revision, with one call button. Same 146° WDR camera, two lock relays and RS-485 module bus as the standard DS-KD8003-IME1(B), for panels specified in stainless with the /S nametag, keypad and rain-shield parts.
The DS-KD8003-IME1(B)/S is the stainless-steel-fronted version of the DS-KD8003-IME1(B) 2 MP main unit, keeping the single call button. Hikvision publishes it on its own page with the same specification as the acrylic unit; its image shows the stainless front with button, and the /S suffix is the finish Hikvision uses across the KD8 range for its stainless parts — the DS-KD-KK/S and DS-KD-K12/S nametag modules, the DS-KD-KP/S keypad and the DS-KABD8003-RS2/S rain shield. For a stainless panel without a call button on the main unit, see the DS-KD8003-IME1(B)/NS.
Hikvision's KD8 modular door station is built from a main unit (camera, microphone, speaker and one call button) plus sub-modules that clip into a common frame: nametag buttons, card reader, keypad, display, indicator and induction loop. Modules connect to the main unit over RS-485 and take their 12 VDC from it, so a panel for a block of flats is specified module by module. Tell us the flat count and the entrance and we will draw up the frame, modules and rain shield.
This is part of Hikvision's IP video intercom range: door stations, indoor stations and accessories that connect over a standard network (PoE or 12 VDC) and are configured with the iVMS-4200 client or the Hik-Connect app. IP-series products are designed to be used together within that range. If you are adding to an existing system, tell us what is installed and we will confirm what fits before you order.
A 2 MP sensor with a wide 146° horizontal by 82° vertical field of view, WDR for a visitor backlit by the street and low-illumination IR supplement lighting for night. Compression is H.265, H.264 or MJPEG, and the stream can be pulled into a recorder over RTSP/ONVIF. Audio is a built-in omnidirectional microphone and loudspeaker with noise suppression and echo cancellation.
Two lock relays rated 30 VDC 2 A, two exit-button inputs and two door-contact inputs cover an outer and inner door; four alarm inputs (two exit buttons and two door contacts by default) and a tamper switch complete the local I/O. The RS-485 port is dedicated to Hikvision sub-modules — nametag buttons, keypad, EM reader, indicator, induction loop and touch display — which take their 12 VDC from the main unit. Local memory holds 2000 users and 6000 cards (via a reader module).
Up to 500 linked indoor stations and 16 sub door stations per system; protocols TCP/IP, RTSP, IPv6 and ONVIF over a 10/100 Mbps RJ45. Power is PoE 802.3af or 12 VDC 500 mA, consumption ≤ 5 W. IP65, -40 °C to 60 °C, surface or flush mounting. Linux with 32 MB ROM and 256 MB RAM.
| Camera | |
|---|---|
| Lens | 2 MP HD camera |
| Resolution | 2 MP |
| FOV | Horizontal: 146°, Vertical: 82° |
| Wide Dynamic Range (WDR) | Support |
| Supplement Light | Low illumination, IR supplement lights |
| Video Compression Standard | H.264; H.265; MJPEG |
| Audio | |
| Audio Input | 1 built-in omnidirectional microphone |
| Audio Output | 1 built-in loudspeaker |
| Audio Compression Standard | G.711 U, G.711 A, Opus, AAC-LD, AAC-LC, G.726, G.722.1 |
| Audio Compression Bitrate | 64 Kbps |
| Audio Quality | Noise suppression and echo cancellation |
| Volume Adjustment | Adjustable |
| Capacity | |
| User Capacity | 2000 |
| Card Capacity | 6000 |
| Linked Indoor Station Capacity | 500 |
| Sub Door Station Capacity | 16 |
| Network | |
| Network Protocol | TCP/IP, RTSP, IPv6, ONVIF |
| Network Interface | 1 RJ-45, 10/100 Mbps self-adaptive |
| Interfaces | |
| Alarm Input | 4 (2 exit buttons and 2 door contacts by default) |
| Exit Button | 2 (2 for lock control) |
| Door Contact Input | 2 |
| Lock Control | 2 relays, Max. 30 VDC, 2 A |
| RS-485 | 1 (1 for Hikvision's sub module communication) |
| TAMPER | 1 |
| Button | 1 |
| General | |
| Installation | Surface mounting, flush mounting |
| Protective Level | IP65 |
| Working Temperature | -40 °C to 60 °C (-40 °F to 140 °F) |
| Application Environment | Outdoor |
| Power Supply | 12 VDC, 500 mA, IEEE 802.3af PoE |
| Power Consumption | ≤ 5 W |
| Operation System | Linux |
| Processor | Embedded high performance processor |
| ROM | 32 MB |
| RAM | 256 MB |
| Model | DS-KD8003-IME1(B)/S |
Hikvision's page allows 500 linked indoor stations and 16 sub door stations. Call buttons are added with DS-KD-KK/S (6) or DS-KD-K12 (12) modules, or replaced by a keypad or touch-display directory.
2 MP with a 146° horizontal field of view, WDR and IR supplement light.
Yes — two relays rated 30 VDC 2 A, with two exit-button inputs and two door-contact inputs.
The main unit: sub-modules take RS-485 and 12 VDC from it through the module cables.
The front finish: /S is Hikvision's stainless-steel version. The published specification is otherwise the same, including the single call button.
The DS-KD8003-IME1(B)/NS — the same stainless main unit with no call button, for panels where calling is by keypad, nametag module or touch display.
Zenith Security Co is an authorised Hikvision partner supplying genuine UK-specification stock. Prices shown are for trade account holders — contact us for account terms and stock, call 01902 902251, or collect from our Wolverhampton trade counter. Browse all intercoms, the wider access control range, or the full Hikvision range.
| Product Code | DS-KD8003-IME1(B)/S |
|---|---|
| Manufacturer | Hikvision |
| Interface | 2 lock relays (30 VDC 2 A), 2 exit buttons, 2 door contacts, 4 alarm inputs, RS-485 (sub-modules), RJ45, tamper |
| Power | 12 VDC 500 mA or PoE (802.3af); ≤ 5 W |
| Operating Temperature | -40 °C to 60 °C |
We provide tailored support for you and your CCTV system.
Many of our Cameras and Recorders come with a comprehensive 3 year warranty.
We've got a fully functioning show room and IP suite to show you exactly how our CCTV equipment works
As cheap as £10, we will deliver your order 3 to 5 working days!